2 AWG 15kV Aluminum URD Cable 133% Insulation | Full Neutral

Parent SKU :  ALURD-15K-2

SKU :  ALURD-15K-2-250

TR-XLPE INSULATION. RATED FOR DIRECT BURIAL. STRANDED ALUMINUM.
Wire Size 2 AWG
Conductor Material Aluminum
Strand Count 7
Outer Diameter 1.07 in. / 27.18 mm
Voltage Rating 15kV
Weight per Foot 0.534 lb

Product Details

Product Details

"The heavy-duty utility standard for 15kV residential power—engineered with 133% TR-XLPE insulation and water-blocked conductors to ensure maximum reliability in underground primary loops."

Why Utilities Specify the #2 AWG 15kV 133% URD

This 15kV aluminum cable is specifically built for long-term underground residential distribution (URD). By using a 133% insulation level, it provides extra protection against voltage surges and insulation degradation.

  • Water-Blocked Stranded Conductors: The interstitial spaces between conductor strands are filled with a specialized compound to prevent longitudinal moisture migration, protecting the core of your cable from the inside out.

  • 133% TR-XLPE Insulation: Featuring 220 mils of Tree-Retardant XLPE, this cable offers superior resistance to "water treeing" and electrochemical failure compared to standard 100% rated cables.

  • Full Concentric Neutral: With 10 x #14 AWG solid bare copper wires, this cable provides a 100% neutral capacity, making it a safe choice for single-phase residential grounding and return current.

  • Durable LLDPE Jacket: The black linear low-density polyethylene jacket is engineered for sunlight, abrasion, and heat resistance, meeting NESC standards for direct burial.

Common 15kV 133% Applications

  • Primary Residential Feeders: Used for underground distribution in high-watertable areas where extra insulation thickness is required.

  • Critical Municipal Infrastructure: Providing primary power for street lighting and municipal grids where 133% insulation levels are mandated for safety.

  • Industrial Primary Service: Suitable for direct burial or conduit installation in wet or dry commercial locations.

Technical Specifications

ENGINEERING OVERVIEW: #2 AWG 133% PRIMARY The #2 AWG 15kV URD is optimized for utility and commercial primary distribution where 1350 series aluminum conductors provide a high-strength, cost-effective solution. This specific model features a Full (100%) concentric neutral and 220 mils of TR-XLPE insulation for enhanced grid reliability.

  • APPLICATION: Used for underground distribution in wet or dry locations, via direct burial or conduit.

  • VOLTAGE: Rated for 15,000 volts or less.

  • CONDUCTORS: #2 AWG 1350 series aluminum. Stranded conductors include water-block filling compound.

  • INSULATION: 220 mils of TR-XLPE (Tree-Retardant Cross-Linked Polyethylene) at 133% insulation level.

  • CONCENTRIC NEUTRAL: 10 x #14 AWG solid bare copper wires helically applied for Full Neutral conductivity.

  • JACKET: Black LLDPE with three red stripes and NESC lightning bolt marking.

  • WEIGHT: Approximately 534 lbs/kft (for #2 STR).

INDUSTRY STANDARDS & COMPLIANCE:

  • UL Listed: Type MV-90

  • Standards: ANSI/ICEA S-94-649, AEIC CS-8, and ASTM B230/B231/B609

  • RUS ACCEPTED

  • Temperature Ratings: 90°C (Normal), 130°C (Emergency), 250°C (Short Circuit)

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

 

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 1.07 in. / 27.18 mm
Jacket Type LLDPE
Conductor Count 1
Shield Shielded
Insulation Type TR-XLPE
UL Listing Numbers UL - MV90

Technical Specifications

Voltage Rating 15kV
Direct Burial Rating Yes
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B230, B231, B609
ANSI/ICEA S-94-649
UL - MV90
AEIC CS-8
RUS ACCEPTED
For 90°C continuous, 130°C emergency and 250°C shortcircuit operation
Miscellaneous Information All values are nominal and subject to correction.

Packaging & Dimensions:

Weight per Foot 0.534 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum URD Medium Voltage Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 4/0 Aluminum URD, 35kV 100% Insulation with Full Neutral Cable.

2 AWG 15kV Aluminum URD Cable 133% Insulation | Full Neutral

Parent SKU :  ALURD-15K-2

SKU :  ALURD-15K-2-250

TR-XLPE INSULATION. RATED FOR DIRECT BURIAL. STRANDED ALUMINUM.
In Stock
Ships in 1-2 days

Parent SKU :  ALURD-15K-2

SKU :  ALURD-15K-2-250

$1,995/ea.
$3,989/ea.
$7,917/ea.
$19,691/ea.
$8.09/ft.
Please select an option
Min: 100 ft., Max: 10,000 ft.
Spool (250 ft.)
$1,995.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details

"The heavy-duty utility standard for 15kV residential power—engineered with 133% TR-XLPE insulation and water-blocked conductors to ensure maximum reliability in underground primary loops."

Why Utilities Specify the #2 AWG 15kV 133% URD

This 15kV aluminum cable is specifically built for long-term underground residential distribution (URD). By using a 133% insulation level, it provides extra protection against voltage surges and insulation degradation.

  • Water-Blocked Stranded Conductors: The interstitial spaces between conductor strands are filled with a specialized compound to prevent longitudinal moisture migration, protecting the core of your cable from the inside out.

  • 133% TR-XLPE Insulation: Featuring 220 mils of Tree-Retardant XLPE, this cable offers superior resistance to "water treeing" and electrochemical failure compared to standard 100% rated cables.

  • Full Concentric Neutral: With 10 x #14 AWG solid bare copper wires, this cable provides a 100% neutral capacity, making it a safe choice for single-phase residential grounding and return current.

  • Durable LLDPE Jacket: The black linear low-density polyethylene jacket is engineered for sunlight, abrasion, and heat resistance, meeting NESC standards for direct burial.

Common 15kV 133% Applications

  • Primary Residential Feeders: Used for underground distribution in high-watertable areas where extra insulation thickness is required.

  • Critical Municipal Infrastructure: Providing primary power for street lighting and municipal grids where 133% insulation levels are mandated for safety.

  • Industrial Primary Service: Suitable for direct burial or conduit installation in wet or dry commercial locations.

Technical Specifications

ENGINEERING OVERVIEW: #2 AWG 133% PRIMARY The #2 AWG 15kV URD is optimized for utility and commercial primary distribution where 1350 series aluminum conductors provide a high-strength, cost-effective solution. This specific model features a Full (100%) concentric neutral and 220 mils of TR-XLPE insulation for enhanced grid reliability.

  • APPLICATION: Used for underground distribution in wet or dry locations, via direct burial or conduit.

  • VOLTAGE: Rated for 15,000 volts or less.

  • CONDUCTORS: #2 AWG 1350 series aluminum. Stranded conductors include water-block filling compound.

  • INSULATION: 220 mils of TR-XLPE (Tree-Retardant Cross-Linked Polyethylene) at 133% insulation level.

  • CONCENTRIC NEUTRAL: 10 x #14 AWG solid bare copper wires helically applied for Full Neutral conductivity.

  • JACKET: Black LLDPE with three red stripes and NESC lightning bolt marking.

  • WEIGHT: Approximately 534 lbs/kft (for #2 STR).

INDUSTRY STANDARDS & COMPLIANCE:

  • UL Listed: Type MV-90

  • Standards: ANSI/ICEA S-94-649, AEIC CS-8, and ASTM B230/B231/B609

  • RUS ACCEPTED

  • Temperature Ratings: 90°C (Normal), 130°C (Emergency), 250°C (Short Circuit)

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

 

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 1.07 in. / 27.18 mm
Jacket Type LLDPE
Conductor Count 1
Shield Shielded
Insulation Type TR-XLPE
UL Listing Numbers UL - MV90

Technical Specifications

Voltage Rating 15kV
Direct Burial Rating Yes
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B230, B231, B609
ANSI/ICEA S-94-649
UL - MV90
AEIC CS-8
RUS ACCEPTED
For 90°C continuous, 130°C emergency and 250°C shortcircuit operation
Miscellaneous Information All values are nominal and subject to correction.

Packaging & Dimensions:

Weight per Foot 0.534 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum URD Medium Voltage Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 4/0 Aluminum URD, 35kV 100% Insulation with Full Neutral Cable.

Physical Specifications

Wire Size (AWG/MCM) 2 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 1.07 in. / 27.18 mm
Jacket Type LLDPE
Conductor Count 1
Shield Shielded
Insulation Type TR-XLPE
UL Listing Numbers UL - MV90

Technical Specifications

Voltage Rating 15kV
Direct Burial Rating Yes
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B230, B231, B609
ANSI/ICEA S-94-649
UL - MV90
AEIC CS-8
RUS ACCEPTED
For 90°C continuous, 130°C emergency and 250°C shortcircuit operation
Miscellaneous Information All values are nominal and subject to correction.

Packaging & Dimensions:

Weight per Foot 0.534 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

The overall jacket diameter for #2 AWG STR 15kV 133% URD is approximately 1.07 inches. For a single-conductor installation, a 2-inch conduit is standard. For a triplex configuration (three cables), a 3-inch or 3.5-inch conduit is recommended to maintain the NEC-mandated 40% fill capacity.
Note on Conduit Sizing: These recommendations are based on standard NEC 40% fill guidelines for general informational purposes. Because factors such as pull length, total degrees of bends, and pulling tension vary by project, always consult with a licensed electrical engineer or project lead to verify final conduit specifications and ensure local code compliance.

This #2 AWG cable features 10 x #14 AWG solid bare copper neutral wires. These wires are helically applied and uniformly spaced over the insulation shield. This provides 100% (Full) conductivity relative to the aluminum center conductor, which is a critical safety requirement for many single-phase residential primary systems.

15kV Aluminum URD (Underground Residential Distribution) cable is a medium-voltage cable used for primary underground power distribution at 15,000 volts or less. It features an aluminum conductor, solid or stranded, with Tree-Retardant Cross-Linked Polyethylene (TR-XLPE), rated for direct burial or duct installation in wet/dry locations.

RUS Accepted means this cable meets the technical and durability standards set by the Rural Utilities Service (USDA). This designation is vital for contractors working on federally funded rural electrification or utility projects, as it guarantees the cable has been vetted for long-term reliability in utility-grade infrastructure.

The 133% insulation level provides a thicker 220-mil wall of TR-XLPE, compared to the 175-mil wall found on standard 100% rated cables. This extra thickness offers a higher safety margin and superior protection against voltage surges, specifically in systems where fault-clearing times might be slower.

The minimum bending radius for #2 AWG STR 15kV URD is approximately 13 inches. Per industry standards, the radius should be at least 12 times the overall diameter of the cable. Adhering to this limit during installation is critical to avoid mechanical stress on the insulation shield and copper neutrals, which could lead to premature electrical failure.

Yes, 15kV URD Cable is rated for direct burial or installation in conduits.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us