FIRE ALARM CABLE NYC CERTIFIED

NYC Certified Plenum Rated Fire Alarm Cable is used for wiring fire alarms, smoke detectors, voice communications, burglar alarms, and approved for NYC LL39 (formerly LL5) fire protective circuits installed in the City of New York. Applications not to exceed 300 volts, suitable for use up to 200°C. Read our NYC Certified Fire Alarm Buyers Guide.

Need a quote?  Call us at: 833-268-8644 or email: sales@wireamerica.com

Filters

0 Products

FIlters

NYC CERTIFIED FIRE ALARM CABLE

NYC Certified Fire Alarm Cable is a specialized signaling conductor engineered to meet the stringent safety standards of the New York City Building and Electrical Codes. Specifically designed for use in the city’s high-rise commercial buildings, schools, and residential complexes, these cables are manufactured to comply with Local Law 39 (LL39) requirements. Featuring solid or stranded bare copper conductors and a high-performance, flame-retardant outer jacket—typically colored red for easy identification—this cable ensures the integrity of life-safety systems during an emergency. Whether used for smoke detectors, pull stations, or voice evacuation systems, Wire America’s NYC-certified cable provides the reliability and heat resistance necessary to maintain critical communication lines when they are needed most.

Key Features
  • NYC Code Compliant: Specifically engineered and certified to meet New York City’s unique electrical standards and Local Law 39 requirements.
  • FPLP/FPLR Rated: Available in Power-Limited Plenum (FPLP) for air-handling spaces and Riser (FPLR) for vertical shafts.
  • High-Visibility Jacket: Encased in a durable, flame-retardant red PVC jacket to ensure immediate identification by inspectors and maintenance crews.
  • Oxygen-Free Copper: Utilizes high-purity bare copper conductors to ensure optimal signal clarity and low attenuation for fire signaling.
  • Easy Strip Design: Features a specialized jacket compound that allows for fast, clean stripping to speed up installation and termination at control panels.
  • Temperature Resistance: Designed to maintain electrical performance in high-heat environments typically found in building fire scenarios.
  • Industry Standards: Manufactured to meet UL 1424 specifications and NEC Article 760 for Power-Limited Fire Alarm Circuits.
Common Applications
  • High-Rise Life Safety Systems: The mandated choice for fire alarm systems in Manhattan and the five boroughs' commercial high-rise buildings.
  • Smoke & Heat Detectors: Provides the primary signaling path from ceiling-mounted sensors to the main fire alarm control panel (FACP).
  • Voice Evacuation Systems: Used to power emergency loudspeakers and mass notification systems in public assembly areas.
  • Manual Pull Stations: Reliable wiring for wall-mounted emergency pull stations located in corridors and near exits
  • Sprinkler Monitoring: Connects flow switches and tamper switches from the fire suppression system to the monitoring station.
  • Hospital & School Safety: Essential for fire protection systems in healthcare facilities and educational institutions requiring NYC-certified components.
  • Fire Damper Control: Used to signal fire dampers to close within HVAC ductwork to prevent the spread of smoke and flames.