2/0 Copper XHHW-2 Building Wire

Parent SKU :  XHW2/0

SKU :  XHW2/0-250-BK

ABRASION & SUNLIGHT-RESISTANT XLP INSULATION FOR EASY PULL & MAXIMUM DURABILTY
Wire Size 2/0
Conductor Material Stranded Copper
Strand Count 19
Outer Diameter 0.53 in. / 13.462 mm
Ampacity Rating 195
Weight per Foot 0.453 lb

Product Details

Product Details

APPLICATION:
XHHW-2 Copper Wire is primarily used for power distribution in conduit or other recognized raceways for services, feeders, and branch circuit wiring as specified in the National Electrical Code. The wire is suitable for use in wet or dry locations at temperatures not exceeding 90°C and is Dual-Rated for 600V or 1000V. 1/0AWG and larger are approved for cable tray use.

CONDUCTOR:
Soft drawn bare copper in compressed stranding.

INSULATION:
Abrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP), low coefficient of friction. It is available in ten solid colors.

AMP RATING:
@ 90°C - 195 Amps


All values are nominal and subject to correction. *Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30°C per Table 310.16 of the National Electrical Code. **Overcurrent protection shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2/0
Conductor Material Stranded Copper
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 0.53 in. / 13.462 mm
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 1685

Technical Specifications

Voltage Rating 600V
Ampacity Rating 195
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44
UL 1685
RoHS Compliant
ASTM B3, B8
ANSI/ICEA S-95-658/NEMA WC-70
NFPA 70 NEC
XLPE -40°C FT1
Federal Spec A-A-59553
Miscellaneous Information All values are nominal and subject to correction. *Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30°C per Table 310.16 of the National Electrical Code. **Overcurrent protection shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC.
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsMain service entrance cables, feeders, branch circuit wiring in conduit and ducts, power distribution, lighting, and control circuits.
Common Uses
  • Service Entrances
  • Branch Circuitry
  • Underground Conduit
  • Battery Storage
  • Water Treatment Plants
  • Refineries
  • Chemical Plants
  • and Inverter Connections.

Packaging & Dimensions:

Weight per Foot 0.453 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

2/0 Copper XHHW-2 Building Wire

Parent SKU :  XHW2/0

SKU :  XHW2/0-250-BK

ABRASION & SUNLIGHT-RESISTANT XLP INSULATION FOR EASY PULL & MAXIMUM DURABILTY
In Stock
Ships in 1-2 days

Parent SKU :  XHW2/0

SKU :  XHW2/0-250-BK

Please select
Please select an option
$1,675/ea.
$3,332/ea.
$6,630/ea.
$16,490/ea.
$32,810/ea.
$6.80/ft.
Please select an option
Min: 250 ft., Max: 20,000 ft.
Spool (250 ft.)
$1,675.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details

APPLICATION:
XHHW-2 Copper Wire is primarily used for power distribution in conduit or other recognized raceways for services, feeders, and branch circuit wiring as specified in the National Electrical Code. The wire is suitable for use in wet or dry locations at temperatures not exceeding 90°C and is Dual-Rated for 600V or 1000V. 1/0AWG and larger are approved for cable tray use.

CONDUCTOR:
Soft drawn bare copper in compressed stranding.

INSULATION:
Abrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP), low coefficient of friction. It is available in ten solid colors.

AMP RATING:
@ 90°C - 195 Amps


All values are nominal and subject to correction. *Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30°C per Table 310.16 of the National Electrical Code. **Overcurrent protection shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2/0
Conductor Material Stranded Copper
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 0.53 in. / 13.462 mm
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 1685

Technical Specifications

Voltage Rating 600V
Ampacity Rating 195
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44
UL 1685
RoHS Compliant
ASTM B3, B8
ANSI/ICEA S-95-658/NEMA WC-70
NFPA 70 NEC
XLPE -40°C FT1
Federal Spec A-A-59553
Miscellaneous Information All values are nominal and subject to correction. *Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30°C per Table 310.16 of the National Electrical Code. **Overcurrent protection shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC.
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsMain service entrance cables, feeders, branch circuit wiring in conduit and ducts, power distribution, lighting, and control circuits.
Common Uses
  • Service Entrances
  • Branch Circuitry
  • Underground Conduit
  • Battery Storage
  • Water Treatment Plants
  • Refineries
  • Chemical Plants
  • and Inverter Connections.

Packaging & Dimensions:

Weight per Foot 0.453 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 2/0
Conductor Material Stranded Copper
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 0.53 in. / 13.462 mm
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 1685

Technical Specifications

Voltage Rating 600V
Ampacity Rating 195
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44
UL 1685
RoHS Compliant
ASTM B3, B8
ANSI/ICEA S-95-658/NEMA WC-70
NFPA 70 NEC
XLPE -40°C FT1
Federal Spec A-A-59553
Miscellaneous Information All values are nominal and subject to correction. *Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30°C per Table 310.16 of the National Electrical Code. **Overcurrent protection shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC.
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsMain service entrance cables, feeders, branch circuit wiring in conduit and ducts, power distribution, lighting, and control circuits.
Common Uses
  • Service Entrances
  • Branch Circuitry
  • Underground Conduit
  • Battery Storage
  • Water Treatment Plants
  • Refineries
  • Chemical Plants
  • and Inverter Connections.

Packaging & Dimensions:

Weight per Foot 0.453 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us
AWG, or American Wire Gauge, is the standard system used primarily in North America to measure the diameter of electrical conductors. This system is critical because a wire's size directly impacts its electrical resistance and how much current (ampacity) it can safely carry. A key principle is that the smaller the AWG number, the larger the wire's diameter; for instance, 12 AWG is thicker and can carry more current than 14 AWG. Sizes beyond 0 AWG are referred to as "aught" (e.g., 1/0, 2/0). Selecting the correct AWG is essential for safe electrical installations, preventing overheating, and minimizing voltage drop.
Voltage drop is the natural reduction in electrical potential that occurs as current travels through a circuit, from the power source to a device. This happens because all wires inherently have resistance, which converts some electrical energy into heat, leading to a loss of voltage. While minor voltage drop is normal, excessive amounts can cause problems like dimming lights, slow or overheating motors, and erratic electronic behavior. It can also lead to higher energy consumption and, in severe cases, create safety hazards due to overheating wires. Key factors influencing voltage drop include the wire's length and thickness (gauge), the amount of current flowing through it, and the quality of electrical connections.
In electrical wiring, amps (amperes) measure the rate of electrical current flow. Think of it as the volume of electricity moving through the wire at any given time. Crucially, every electrical wire has an ampacity rating, which is the maximum current it can safely carry continuously without overheating. Exceeding a wire's ampacity can lead to insulation damage and fire hazards, highlighting why proper wire sizing based on expected amperage is vital for safe electrical systems.
A wire's ampacity, or its safe current-carrying capacity, changes with temperature primarily because of two factors. First, the electrical resistance of copper and aluminum wires increases as they get hotter, causing them to generate more heat when current flows. Second, every wire's insulation has a maximum temperature limit; exceeding this can cause degradation and safety hazards. Therefore, in hotter environments, a wire must carry less current to avoid exceeding its insulation's temperature rating. This ensures the wire remains safe and functional, preventing overheating and potential failures.
We aim to provide authentic, precise images of each wire; however, with various product variations, it can be challenging. In such instances, we focus on showcasing the fundamental design. Always refer to the product specifications rather than relying solely on images.
Call Us. Icon

Call Us.

(833) 268-8644