10 AWG High Temp SIS Switchboard Wire - 125°C

Parent SKU :  10SIS-3173

SKU :  10SIS-3173-500-BK

UL 3173. DESIGNED FOR INTERNAL WIRING OF CONTROL PANELS AND ELECTRICAL SWITCHGEAR.
Wire Size 10 AWG
Conductor Type Stranded
Outer Diameter 0.181 in. / 4.60 mm
Conductor Count 1
Voltage Rating 600V
Temperature Rating 125ºC

Product Details

Product Details
SWITCHBOARD SIS WIRE is for use in switchboards for control and power circuits, for applications up to 125°C and 600 volts.

CONDUCTOR:
Stranded soft drawn tinned coated copper conductor per ASTM B33, B174.

INSULATION:
Cross-linked polyethylene (XLP) insulation

TEMPERATURE RATING:
125ºC / 257ºF

UL LISTING:
UL 3173

CABLE WEIGHT:
0.043 lbs/ft.



All values are nominal and subject to correction.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 10 AWG
Conductor Material Tinned Copper
Conductor Type Stranded
Strand Count 104
Outer Diameter (OD) (in/mm) 0.181 in. / 4.60 mm
Conductor Count 1
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 3173

Technical Specifications

Voltage Rating 600V
Submersible No
Temperature Rating 125ºC
Standards UL Type AWM Style 3173
CSA CL1251
UL Horizontal Flame Test
CSA FT2 Flame Test
Miscellaneous Information All values are nominal and subject to correction.

Usage & Installation

Primary ApplicationsSwitchboards, Control and Power Circuits, Applications up to 125° and 600 volts.
Common Uses
  • Large electrical switchgear
  • substations
  • distribution panels
  • circuit breakers
  • relays
  • contactors
  • terminal blocks
  • motor
  • coil leads
  • lighting fixtures
  • computers.

Packaging & Dimensions:

Weight per Foot 0.043 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

10 AWG High Temp SIS Switchboard Wire - 125°C

Parent SKU :  10SIS-3173

SKU :  10SIS-3173-500-BK

UL 3173. DESIGNED FOR INTERNAL WIRING OF CONTROL PANELS AND ELECTRICAL SWITCHGEAR.
In Stock
Ships in 1-2 days

Parent SKU :  10SIS-3173

SKU :  10SIS-3173-500-BK

$324/ea.
$644/ea.
$1,601/ea.
Please select an option
Min: 500 ft., Max: 5000 ft.
Spool (500 ft.)
$324.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details
SWITCHBOARD SIS WIRE is for use in switchboards for control and power circuits, for applications up to 125°C and 600 volts.

CONDUCTOR:
Stranded soft drawn tinned coated copper conductor per ASTM B33, B174.

INSULATION:
Cross-linked polyethylene (XLP) insulation

TEMPERATURE RATING:
125ºC / 257ºF

UL LISTING:
UL 3173

CABLE WEIGHT:
0.043 lbs/ft.



All values are nominal and subject to correction.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 10 AWG
Conductor Material Tinned Copper
Conductor Type Stranded
Strand Count 104
Outer Diameter (OD) (in/mm) 0.181 in. / 4.60 mm
Conductor Count 1
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 3173

Technical Specifications

Voltage Rating 600V
Submersible No
Temperature Rating 125ºC
Standards UL Type AWM Style 3173
CSA CL1251
UL Horizontal Flame Test
CSA FT2 Flame Test
Miscellaneous Information All values are nominal and subject to correction.

Usage & Installation

Primary ApplicationsSwitchboards, Control and Power Circuits, Applications up to 125° and 600 volts.
Common Uses
  • Large electrical switchgear
  • substations
  • distribution panels
  • circuit breakers
  • relays
  • contactors
  • terminal blocks
  • motor
  • coil leads
  • lighting fixtures
  • computers.

Packaging & Dimensions:

Weight per Foot 0.043 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 10 AWG
Conductor Material Tinned Copper
Conductor Type Stranded
Strand Count 104
Outer Diameter (OD) (in/mm) 0.181 in. / 4.60 mm
Conductor Count 1
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 3173

Technical Specifications

Voltage Rating 600V
Submersible No
Temperature Rating 125ºC
Standards UL Type AWM Style 3173
CSA CL1251
UL Horizontal Flame Test
CSA FT2 Flame Test
Miscellaneous Information All values are nominal and subject to correction.

Usage & Installation:

Primary ApplicationsSwitchboards, Control and Power Circuits, Applications up to 125° and 600 volts.
Common Uses
  • Large electrical switchgear
  • substations
  • distribution panels
  • circuit breakers
  • relays
  • contactors
  • terminal blocks
  • motor
  • coil leads
  • lighting fixtures
  • computers.

Packaging & Dimensions:

Weight per Foot 0.043 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us
AWG, or American Wire Gauge, is the standard system used primarily in North America to measure the diameter of electrical conductors. This system is critical because a wire's size directly impacts its electrical resistance and how much current (ampacity) it can safely carry. A key principle is that the smaller the AWG number, the larger the wire's diameter; for instance, 12 AWG is thicker and can carry more current than 14 AWG. Sizes beyond 0 AWG are referred to as "aught" (e.g., 1/0, 2/0). Selecting the correct AWG is essential for safe electrical installations, preventing overheating, and minimizing voltage drop.
Voltage drop is the natural reduction in electrical potential that occurs as current travels through a circuit, from the power source to a device. This happens because all wires inherently have resistance, which converts some electrical energy into heat, leading to a loss of voltage. While minor voltage drop is normal, excessive amounts can cause problems like dimming lights, slow or overheating motors, and erratic electronic behavior. It can also lead to higher energy consumption and, in severe cases, create safety hazards due to overheating wires. Key factors influencing voltage drop include the wire's length and thickness (gauge), the amount of current flowing through it, and the quality of electrical connections.
In electrical wiring, amps (amperes) measure the rate of electrical current flow. Think of it as the volume of electricity moving through the wire at any given time. Crucially, every electrical wire has an ampacity rating, which is the maximum current it can safely carry continuously without overheating. Exceeding a wire's ampacity can lead to insulation damage and fire hazards, highlighting why proper wire sizing based on expected amperage is vital for safe electrical systems.
A wire's ampacity, or its safe current-carrying capacity, changes with temperature primarily because of two factors. First, the electrical resistance of copper and aluminum wires increases as they get hotter, causing them to generate more heat when current flows. Second, every wire's insulation has a maximum temperature limit; exceeding this can cause degradation and safety hazards. Therefore, in hotter environments, a wire must carry less current to avoid exceeding its insulation's temperature rating. This ensures the wire remains safe and functional, preventing overheating and potential failures.
We aim to provide authentic, precise images of each wire; however, with various product variations, it can be challenging. In such instances, we focus on showcasing the fundamental design. Always refer to the product specifications rather than relying solely on images.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us